I would like to turn on the audit logging with a wsadmin script. I was able to create the audit notification like this:
AdminTask.createAuditNotification('[-notificationName Log_Notification -sendEmail false -emailList -logToSystemOut true ]')
But I can't create the auditnotification monitor, becasuse it needs to have the notificationRef:
AdminTask.createAuditNotificationMonitor('[-monitorName AuditMonitor -notificationRef WSNotification_1428567470299 -enable true ]')
and if I want to get that ref (AdminTask.getAuditNotificationRef()) to put it in a variable, then it needs to have the monitor configured first (according to the IBM documentation). If I do not configure the notification monitor first, then the getAuditNotificationRef will return with null value. But if I want to configure the monitor, I need the notificationRef :(.
Kind of confusing stuff for me...could anyone help me with this issue?
thanks
Have you looked in the knowledgecenter?
http://www-01.ibm.com/support/knowledgecenter/SSAW57_8.5.5/com.ibm.websphere.nd.doc/ae/txml_7auditnotify.html?lang=en
This shows the following example:
AdminTask.createAuditNotification('-notificationName defaultEmailNotification
-logToSystemOut true -sendEmail true -emailList administrator#mycompany.com(smtp-server.mycompany.com)
-emailFormat HTML')
AdminTask.createAuditNotificationMonitor('-notificationName defaultEmailNotification
-logToSystemOut true -sendEmail true -emailList administrator#mycompany.com(smtp-server.mycompany.com)
-emailFormat HTML')
AdminConfig.save()
As you can see, there is no -notificationRef needed.
Regards,
Gary
Related
I have a SKNode that is running different actions.
Depending on the running action I want to trigger other behaviours. For that I would need to find out how to check which action is currently running on my SKNode.
I know of .hasActions() but this is returning a general true/false value, which does not help me in my situation.
Does anyone have a better solution?
Thanks in advance
When you start running an action, you assign a key to it using this method:
yourNode.run(someAction, withKey: "someKey")
You can then get the action with your key using:
yourNode.action(forKey: "someKey")
If the above cal returns nil, that means the node is not running the action!
I'm having an unexpected issue with a c++ quickfix client application using FIX 4.4. I form marketdatarequest and populate it and then call send which returns true. The message is not found in the message or event log files.
No error seems to be reported - what could be happening?
FIX44::MarketDataRequest request(FIX::MDReqID(tmp)
, FIX::SubscriptionRequestType('1')
, FIX::MarketDepth(depth)); // 0 is full depth
FIX::SubscriptionRequestType subType(FIX::SubscriptionRequestType_SNAPSHOT);
FIX44::MarketDataRequest::NoRelatedSym symbolGroup;
symbolGroup.set(FIX::Symbol(I.subID));
request.addGroup(symbolGroup);
FIX::Header &header = request.getHeader();
header.setField(FIX::SenderCompID(sessionSenderID));
header.setField(FIX::TargetCompID(sessionTargetID));
if (FIX::Session::sendToTarget(request) == false)
return false;
My FixConfig looks like:
[DEFAULT]
HeartBtInt=30
ResetOnLogout=Y
ResetOnLogon=Y
ResetOnDisconnect=Y
ConnectionType=initiator
UseDataDictionary=Y
FileLogPath=logs
[SESSION]
FileLogPath=logs
BeginString=FIX.4.4
DataDictionary=XXXXX
ConnectionType=initiator
ReconnectInterval=60
TargetCompID=tCompID
SenderCompID=sCompID
SocketConnectPort=123456
SocketConnectHost=XX.XX.XXX.XX
SocketConnectProtocol=TCP
StartTime=01:05:00
EndTime=23:05:30
FileLogPath=logs
FileStorePath=logs
SocketUseSSL=N
thanks for any help,
Mark
Mark, just couple of notes not really related to your question but which you may found useful:
you dont have to explicitly set TargetCompId/SenderCompId for each message, engine will do it for you.
Do not place logic into callbacks(like you did with market data subscription in onLogon). Better create additional thread which will consume events from you listener, make decisions and take an action.
I'm new to OTRS (3.2) and also new to PERL but I have been given the task of setting up OTRS so that it will make a call to our remote webservice so a record can be created on our end when a ticket is set as "Closed".
I set up various dynamic fields so the customer service rep can fill in additional data that will be passed into the webservice call along with ticket details.
I couldn't get the webservice call to trigger when the ticket was "Closed" but I did get it to trigger when the "priority" was changed so I'm just using that now to test the webservice.
I'm just using the Test.pm and TestSimple.pm files that were included with OTRS.
When I look at the Debugger for the Webserice, I can see that the calls were being made:
$VAR1 = {
'TicketID' => '6'
};
My webservice currently just has one method "create" which just returns true for testing.
however I get the following from the Test.pm
"Got no TicketNumber (2014-09-02 09:20:42, error)"
and the following from the TestSimple.pm
"Error in SOAP call: 404 Not Found at /TARGET/SHARE/var/otrs/Kernel/GenericInterface/Transport/HTTP/SOAP.pm line 578 (2014-09-02 09:20:43, error)
I've spent countless hours on Google but couldn't find anything on this. All I could find is code for the Test.pm and TestSimple.pm but nothing really helpful to help me create a custom invoker for my needs and configure the webservice in OTRS to get it to work.
Does anyone have any sample invokers that I can look at to see how to set it up?
Basically I need to pass the ticket information along with my custom dynamic fields to my webservice. From there I can create the record on my end and do whatever processing.
I'm not sure how to setup the Invoker to pass the necessary ticket fields and dynamic fields and how to make it call a specific method in my remote webservice.
I guess getting the Test.pm and TestSimple.pm to work is the first step then I can modify those for my needs. I have not used PERL at all so any help is greatly appreciated.
I'm also struggling with similar set of requirements too. I've also never programmed in PERL, but I can tell you at least that the "Got no TicketNumber" in the Test.pm is right from the PrepareRequest method, there you can see this block of code:
# we need a TicketNumber
if ( !IsStringWithData( $Param{Data}->{TicketNumber} ) ) {
return $Self->{DebuggerObject}->Error( Summary => 'Got no TicketNumber' );
}
You should change all references to TicketNumber to TicketID, or remove the validation whatsoever (also there is mapping to ReturnedData variable).
Invoking specific methods on your WS interface is quite simple (but poorly documented). The Invoker name that you specify in the "OTRS as requester" section of web service configuration corresponds to the WS method that will be called. So if you have WS interface with a method called "create" just name the Invoker "create" too.
As far as the gathering of dynamic field goes, can't help you on that one yet, sorry.
Cheers
I have a script :
<cfscript>
gf = createObject('component','com.general');
gf.checkIpBlocked();
</cfscript>
that I want to fire onSessionStart.
I added an onSessionStart to /siteID/includes/themes/myTheme/eventHandler.cfc. But the session start NEVER fires. I know there is something managing sessions because of I open the admin, login then close the browser, re-open it I am forced to login again.
If I set a session variable close the browser and and the session.testVar never goes away and seems to hold the initial value for a very long time.
I am not trying to manage mura users or anything I am just trying to set a session variable the first time in a "session". In a typical application.cfc this is easy.
Any insight is appreciated.
Unfortunately, that's a bug. However, one thing to keep in mind is that onSiteSessionStart is unreliable since it only fires when a siteID is defined within the request. For example, if you were to go to the admin and be asked to login your session will have started and there would have been no siteID.
For now I would try using onSiteRequestStart to param the variable instead.
function onSiteRequestStart($){
param name="session.ipChecked" default=false;
if(!session.ipChecked){
var gf = createObject('component','com.general');
gf.checkIpBlocked();
session.ipChecked=true;
}
}
In regard to our documentation we have three Mura 6 books available both printed and digital downloads from Lulu
And are also working to create a systematic way to post the contents of those books on our support site which we are hoping to complete by MuraCon on 9/30. So that the all of our documentation will stay update and in sync.
The Mura docs state that the application events are actually onGlobalSessionStart and/or onSiteSessionStart.
Application Events
onApplicationLoad onSiteSessionStart
onGlobalSessionStart onSiteSessionEnd
onSiteMissingTemplate onSiteError
onGlobalError onBeforeAutoUpdate
onAfterAutoUpdate onGlobalThreatDetect
Note that Events that begin with onGlobal are deļ¬ned on a per-Mura
instance basis.
Mura docs.
I have a system service that handles print requests, and given a printer name from the user, attaches a DC to that printer. It starts a document, ends it, and detatches.
m_PrinterDC.CreateDC (L"WINSPOOL", _printerName.c_str(), NULL, NULL)
m_DC.Attach(m_hprinter)
m_DC.StartDoc(...)
...
mDc.TextOut(...)
...
m_DC.EndDoc()
m_DC.Detatch()
This works fine for normal printers, but when using the "Print to OneNote" functionality (driver name 'Send To OneNote 2010') it doesn't seem to work. I would like to avoid custom logic just for this feature; ideally all printers would work regardless. Any thoughts what might be going wrong? I've tried updating the printer security settings to include Print rights for group everyone; not sure what else to try.
Unfortunately, I have to guess some points, because you seem to avoid detailed description of error condition.
First, if you check all return values are success, just it may be a problem about onenote itself. Check the condition of onenote by printing using other programmes.
Second, did you check if _printerName is exact? If some of users are using other language OS, the driver name, 'Send To OneNote 2010' will be different or depending on version. Of course, if you check all return values of function calls, it recorded in your log file. However, I'm worrying about you used exact printer name by using 'EnumPrinters'.
http://msdn.microsoft.com/en-us/library/windows/desktop/dd162931(v=vs.85).aspx
I hope this helps you a little.